产品搜索:
产品资料
产品[

LDP63100-S进口控制器LDP63100-S特价提供

]资料
如果您对该产品感兴趣的话,可以 sendmsg
产品名称: LDP63100-S进口控制器LDP63100-S特价提供
产品型号: LDP63100-S
产品厂商: 美国Omega热电偶
产品文档: 无相关文档
简单介绍
    LDP63100-S进口控制器LDP63100-S特价提供由美国omega原厂渠道的深圳鑫博恒业科技有限公司特价提供,LDP63100-S进口控制器LDP63100-S特价提供精度高,寿命长,LDP63100-S进口控制器LDP63100-S特价提供是值得信赖的精密仪表.
LDP63100-S进口控制器LDP63100-S特价提供 的详细介绍

LDP63100-S进口控制器LDP63100-S特价提供

LDP63100-S

1/8 DIN Universal Process Panel Meter with built-in USB
DP63100

Built-In USB Programming Port
Modular Output Modules
Universal Process, Voltage, Current, Resistance and Temperature Inputs
Universal AC/DC Power Supply
6/9 Digit Dual Line/ Tri-Color Display with 18 mm (0.71") and 8.9 mm (0.35")
Programmable Units Display
Variable Contrast and Intensity Display
Up to 160 Samples Per Second Conversion Rate
NEMA 4X (IP65) Sealed Front Bezel

 

产品描述
The DP63100 analog process panel meter offers many features and performance capabilities to suit a wide range of industrial applications. The DP63100 has a universal input to handle various input signals including DC voltage/current, process, resistance and temperature. The optional plug-in output cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs. The DP63100 employs a dual line, tri-color display with a large 18 mm (0.71"), tri-color 6 digit top display line and a 8.9 mm (0.35"), 9 digit green bottom display line. The meter provides a MAX and MIN reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.The signal totalizer (integrator) can be used to compute a time-input product. This can be used to provide a readout of totalized flow or calculate service intervals of motors, pumps, etc.
The meter has up to four setpoint outputs, implemented on plug-in option cards. The plug-in cards provide dual FORM-C relays, quad FORM-A, or either quad sinking or quad sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements.
Communication and bus capabilities are also available as option cards. These include RS232 and RS485. The DP63100 can be programmed to utilize MODBUS? protocol. With MODBUS, the user has access to most configuration parameters. Readout values and setpoint alarm values can be controlled through the bus. Additionally, the meter has a feature that allows a remote computer to directly control the outputs of the meter. The DP63100 includes a built-in USB programming port. With a Windows? based program, configuration data can be downloaded to the unit without the need of any additional option cards. A linear DC output signal is available as an optional plug-in card. The card provides either 20 mA or 10V signals. The output can be scaled independent of the input range and can track either the input, totalizer, max or min readings. The meter has been specifically designed for harsh industrial environments. With NEMA 4X (IP65) sealed bezel and extensive testing of noise effects and CE requirements, the meter provides a tough reliable application solution.
SPECIFICATIONS
Display: Negative image LCD
Top Line: 6 digit, 18 mm (0.71"), with tri-color backlight (red, green or orange)
Display Range: -199999 to 999999;
Bottom Line: 9 digit, 8.9 mm (0.35"), with green backlight
Display Range: -199,999,999 to 999,999,999
Power
AC Power: 50 to 250 Vac, 50/60 Hz, 14 VA
DC Power: 21.6 to 250 Vdc, 8 W
Isolation: 2300 Vrms for 1 min to all inputs and outputs. KEYPAD: 3 programmable function keys, 5 keys total
A/D Converter: 24 bit resolution
Update Rates: A/D conversion rate; programmable 5 to 160 readings/sec
Thermocouple Inputs
Readout:
Scale: °F or °C
Offset Range: -199,999 to 999,999 display units
Input Impedance: 20 MO
Lead Resistance Effect: 0.03 μV/Ω
Max Continuous Overvoltage: 30V
RTD Inputs
Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance
Excitation Current: 100 Ω
Range: 136.5 μA ±10%
10 Ω Range: 2.05 mA ±10%
Lead Resistance: 100 Ω
Range: 10 Ω/lead max
10 Ω Range: 3 Ω/lead max
Max Continuous Overload: 30V
Excitation Power: Jumper selectable
Transmitter Power: ±18 Vdc @ 50 mA
Reference Voltage: ±2 Vdc, ±2%
User Inputs
Two Programmable User Inputs Max Continuous Input: 30 Vdc
Isolation to Sensor Input Common: Not isolated
Response Time: 12 msec max
Totalizer
Time Base: Second, minute, hour, or day
Batch: Can accumulate (gate) input display from a user input
Time Accuracy: 0.01% typical
Decimal Point: 0 to 0.0000
Scale Factor: 0.001 to 65.000
Low Signal Cut-Out: -199,999 to 999,999
Total: 6 digits on line 1; 9 digits on line 2
Custom Linearization
Data Point Pairs: Selectable from 2 to 16
Display Range: -199,999 to 999,999
Decimal Point: 0 to 0.0000
Memory: Nonvolatile FRAM memory retains all programmable parameters and display values
Environmental Conditions
Operating Temperature Range: 0 to 50°C (32 to 122°F) 0 to 45°C (32 to 113°F) with all three plug-in cards installed
Storage Temperature Range: -40 to 60°C (-40 to 140°F)
Operating and Storage Humidity: 0 to 85% max RH non-condensing
Altitude: Up to 2000 m (6561')
Connections: High compression age-clamp terminal block
Construction: This unit is rated for NEMA 4X (IP65) outdoor use IP20 touch safe. Installation Category II, pollution degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included.
Dimensions
Case: 44.45 H x 91.44 W x 105 mm D (1.75 x 3.6 x 4.14")
Bezel: 49.53 x 96.52 mm (1.95 x 3.8")
Panel Cutout: 1/8 DIN, 45 x 92 mm (1.77 x 3.62")
Weight: 226.8 g (8 oz)

 

注: Comes complete with operator’s manual.
Adding option cards to meters can be fitted with up to three optional plug-in cards. However, only one card from each function type can be installed at a time. The function types include Setpoint Alarms, Communications, and Analog Output. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions.

 

产品编号   产品描述
DP63100   1/8 DIN universal process panel meter
Accessories
LDP6-CDS10  Dual setpoint relay output card
LDP6-CDS20  Quad setpoint relay output card
  
LDP6-CDS30  Quad setpoint sinking open collector output card
LDP6-CDS40   Quad setpoint sourcing open collector output card
LDP6-CDL10  Analog output card
  
LDP6-CDC10  RS485 serial communications output card with terminal block
  
LDP6-CDC1C   Extended RS485 serial communications output card with dual RJ11 connector
  
LDP6-CDC20   RS232 serial communications output card with terminal block
  
LDP6-CDC2C   Extended RS232 serial communications output card with 9 pin D connector
 

 

产品编号 
DP63100  
LDP6-CDS10
LDP6-CDS20 
LDP6-CDS30 
LDP6-CDS40 
LDP6-CDL10
LDP6-CDC10 
LDP6-CDC1C  
LDP6-CDC20 
LDP6-CDC2C  

 LDP63100-S


LDP63100-S进口控制器LDP63100-S特价提供衍生阅读

LDP63100-S进口控制器LDP63100-S特价提供相关产品

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!


img15
img16
深圳市鑫博恒业科技有限公司 版权所有
电话:0755-82768776 82736276    传真:0755-83041664  电邮 :info@xb5j.cn
地址:深圳市福田区华强北路华强广场A栋17A(华强北地铁站-A口)  邮编:518031
粤ICP备09037369号  

著作权声明
  

粤公网安备 44030402001378号